Halogen-free low-smoke heat-shrinkable marking tube YEVA-DIN

Material standard: ASTM D 2671

Color code robustness standard: SAE AS 81531 and MIL-STD-202G/215K

Fire and Smoke Toxicity Index Standard: DIN 5510-2

Shrinkage ratio: 2:1 and 3:1

Shrinking temperature: 85℃~120℃

Operating temperature: -55℃~+125℃

Environmental standards: RoHS

Standard colors: commonly used yellow and white; other 10 standard colors can be customized

product description:

YEVA-DIN---The halogen-free low-smoke heat-shrinkable marking tube is made of radiation cross-linked polyolefin material, which can meet the special use environment. The main function is the cable interface marking of the signal and power system. It is widely used in rail transit, Fields such as communications, precision instruments, automobiles, ships, spacecraft, aircraft and nuclear power islands.

Features:

Material standard: ASTM D 2671

Color code robustness standard: SAE AS 81531 and MIL-STD-202G/215K

Fire and Smoke Toxicity Index Standard: DIN 5510-2

Shrinkage ratio: 2:1 and 3:1

Shrinking temperature: 85℃~120℃

Operating temperature: -55℃~+125℃

Environmental standards: RoHS

Standard colors: commonly used yellow and white; other 10 standard colors can be customized


Halogen-free low-smoke heat-shrinkable marking tube YEVA-DIN(图1)

ProjectTest MethodsTechnical index
Tensile StrengthISO 37≥10.2 MPa
Elongation at breakISO 37≥250%
After heat aging: tensile strength
Elongation at break
ISO 188(158℃,168 hrs.)≥6.7 MPa
≥100%
Flame retardantDIN 5510-2S3 level
Thermal shockUL 224(225℃,4 hrs.)No cracks, no drips
Axial change rateUL 2242X:-10%~+1%;3X:-15%~+5%
Volume resistivityASTM D 2671≥10^14Ω.cm
Cold-formed flexibilityUL 224(-55℃,1 hrs.)No cracks
Breakdown strengthIEC 60243≥19.7KV/mm
Water absorptionASTM D 570≤1%