Product

Ordinary Heat Shrinkable Tube

Double Wall Heat Shrinkable Tube

High Temperature Heat Shrinkable Tube

Heat Shrinkable Marking Tube

Medium/Thick Wall Heat Shrinkable Tube

High Pressure Heat Shrinkable Tube

Anti-Slip Pattern Heat Shrinkable Tube

Teflon Tube/Silicone Tube

Bellows

Molded Heat Shrinkable Parts

Molded Special-Shaped Protective Box

Insulation Sealing Protective Tape

Product Model Comparison Table

HB1506 low voltage insulation heat shrinkable tape

Specification: 0.4mm (thickness) × 50mm (width) × 10m (length)

Colour: Black

Appearance: Rolled

Working conditions: -40℃~90℃

Packing specification: 50 rolls/carton

HB1506 low-voltage insulation heat-shrinkable tape is a heat-shrinkable insulation tape, suitable for 1kV insulated busbars and cables, and can replace low-voltage heat-shrinkable insulation tubes.

 

product information

Specification: 0.4mm (thickness) × 50mm (width) × 10m (length)

Colour: Black

Appearance: Rolled

Working conditions: -40℃~90℃

Packing specification: 50 rolls/carton

 

Product Features

1. Double-layer structure, the outer layer is insulated and protected, and the inner layer is well bonded and sealed with the entanglement.

2. UV resistance, outdoor aging resistance and mildew resistance.

3. Excellent electrical insulation, good flame retardancy, and high mechanical strength.

 

Scope of application

1. Insulation protection of low-voltage bus.

2. Repair of damaged outer sheath of low-voltage cable.

3. Insulation protection for special parts such as the power leads of subways, tunnels, and electric trains.

 

Instructions for use

Treat the wound parts to ensure that there is no dust. Before winding, use a hair dryer to heat the inner layer of the front end tape to fix it on the surface of the winding. Then wrap it under the object that needs insulation in the form of 1/2 overlap. After the winding is completed, use a hair dryer to evenly heat the inner layer to heat the inner layer. Pull it hard at the end to make the tape wrap itself around and cut it. After that, the tape can melt together by itself.


Test items

Typical parameters

Test based on

Tensile Strength

≥15.0MPa

GB/T 1040-1992

Elongation at break

≤480%

GB/T 1040-1992

Power frequency breakdown

3750V/1min pass

GB/T 1409-1988

Impulse voltage

7500V/±10 times pass

GB311

Volume resistivity

≥1×1014Ω·cm

GB/T 1410-1989

Breakdown strength

≥30kV/mm

GB/T 1408-1989

Oxygen Index

≥27%

GB/T 2406-1993

Heat-resistant stress cracking, 1000h

No cracking, good adhesion

GB/T 1842-4980

Mildew resistance

level 2

GJB4.10-83


Industry Application